New Member RX-7 Technical Post your first technical questions here, in an easy flame free environment, before jumping into the main technical sections.

turboII engine not getting gas?

Thread Tools
 
Search this Thread
 
Old 08-20-09, 08:02 PM
  #1  
mattfromthepier

Thread Starter
 
mattfromthepier's Avatar
 
Join Date: Jan 2007
Location: Merritt Island, FL
Posts: 30
Received 0 Likes on 0 Posts
FL turboII engine not getting gas?

I just finished up putting a 88 t2 engine into an 88 gtu and it has compression and spark but doesnt seem to be getting any fuel. I have a defi fuel pressure gauge installed after the fuel filter and it says it has adequate fuel pressure (70-80psi), but when i try to start the engine it just turns over and over and over and never even tries to start. Also, if i turn it over for a while it doesnt seem to smell like gas in the garage? and i can only smell the marvel mystery oil i poured in the engine if i put my nose right up to the tail pipe after i try to start it. Anyone have any ideas what it could be or had a similiar problem? any kind of help or ideas is greatly appreciated! thanks!
Old 08-20-09, 11:28 PM
  #2  
Top Down, Boost Up

iTrader: (7)
 
RotaryRocket88's Avatar
 
Join Date: Mar 2008
Location: San Diego, CA
Posts: 8,718
Likes: 0
Received 6 Likes on 4 Posts
70-80psi is way too high if you're tee'd into the fuel feed line. You should only see that much if you "deadhead" the line. Normal fuel pressure when the engine is not running is about 40psi. If this is a J-spec engine, you probably have the fuel lines backwards.
Old 08-21-09, 03:21 AM
  #3  
Junior Member

iTrader: (2)
 
Kerberos_8's Avatar
 
Join Date: Jan 2007
Location: Vegas
Posts: 25
Likes: 0
Received 0 Likes on 0 Posts
your injectors are not fireing. I had the same problem. My car was not starting because it wasnt getting fuel. Mine issue turned out to be a broken wire on my crank angle sensor.
Old 08-22-09, 09:57 PM
  #4  
mattfromthepier

Thread Starter
 
mattfromthepier's Avatar
 
Join Date: Jan 2007
Location: Merritt Island, FL
Posts: 30
Received 0 Likes on 0 Posts
FL

Thanks so much rotaryrocket88!! I switched the fuel lines and it started up first try! I feel like an idiot cause i actually knew where the fuel lines were supposed to go on the jspec engine i just screwed up. thanks alot for all suggestions and help you guys! Finally got my year and a half long project on the road! woohoo!!
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Rotospectre
New Member RX-7 Technical
3
03-28-18 03:33 PM
82streetracer
1st Generation Specific (1979-1985)
7
08-23-15 09:28 AM
smikels
2nd Generation Specific (1986-1992)
3
08-18-15 01:26 PM



Quick Reply: turboII engine not getting gas?



All times are GMT -5. The time now is 03:53 PM.