Is my Apex seal gone? Full story, with afterwards testing done....

Thread Tools
 
Search this Thread
 
Old 10-16-05, 10:04 PM
  #51  
Powered by** Rotary

Thread Starter
 
BoOsTin FD's Avatar
 
Join Date: Feb 2002
Location: St. Louis
Posts: 2,369
Received 0 Likes on 0 Posts
Yeah, the problem was with using the Piston engine compression tool, i wasn't able to see if there are any differences in the spikes on the front rotor.

But when i moved it manually and was listening for the puffs, you can definetelly tell one is the loudest and other 2 are kind of low...

Today, i removed the engine and tomorrow i'm gonna remove everything off of it and get it ready for tear down.
Old 10-25-05, 09:40 PM
  #52  
Powered by** Rotary

Thread Starter
 
BoOsTin FD's Avatar
 
Join Date: Feb 2002
Location: St. Louis
Posts: 2,369
Received 0 Likes on 0 Posts
Well, it turns out 1 apex seal is broken on the front rotor. It also messed up my front housing so i need to start shopping for one.

Just wanted to give a little update.
Old 10-26-05, 11:07 AM
  #53  
development

 
dubulup's Avatar
 
Join Date: Aug 2002
Location: Lafayette, LA
Posts: 5,714
Likes: 0
Received 6 Likes on 5 Posts
good luck with the build...careful how hard you push those little hair dryers.

look into WI this build.
Old 10-26-05, 11:42 AM
  #54  
Powered by** Rotary

Thread Starter
 
BoOsTin FD's Avatar
 
Join Date: Feb 2002
Location: St. Louis
Posts: 2,369
Received 0 Likes on 0 Posts
what's a WI?
Old 10-26-05, 12:26 PM
  #55  
Rotary Enthusiast

iTrader: (5)
 
rfreeman27's Avatar
 
Join Date: Oct 2002
Location: MD
Posts: 1,197
Likes: 0
Received 1 Like on 1 Post
Hate to say I told you so...

allright!


good luck with the build, look into ditching thoes stock Peices of junk.

As dub said water injection would be a good idea to keep that charge air temp in check.

-bobby
Old 10-26-05, 03:01 PM
  #56  
Powered by** Rotary

Thread Starter
 
BoOsTin FD's Avatar
 
Join Date: Feb 2002
Location: St. Louis
Posts: 2,369
Received 0 Likes on 0 Posts
what stock pieces of junk? the twins?

I suspected the seal but i wanted to make sure before i took the engine apart.

What do i need water injection for? I think the intake temps were low enough. I'm still not sure why it blew...
Old 10-26-05, 03:51 PM
  #57  
silver ghost

iTrader: (11)
 
G's 3rd Gen's Avatar
 
Join Date: Sep 2003
Location: Home of the Rolex 24
Posts: 3,061
Likes: 0
Received 5 Likes on 5 Posts
could it have been a the primary injector misfiring causing a lean condition? partial clog?
Old 10-26-05, 04:05 PM
  #58  
development

 
dubulup's Avatar
 
Join Date: Aug 2002
Location: Lafayette, LA
Posts: 5,714
Likes: 0
Received 6 Likes on 5 Posts
Originally Posted by BoOsTin FD
I think the intake temps were low enough. I'm still not sure why it blew...

SMIC and 15psi on twins = not cool intake temps.

that's my guess why it blew
Old 10-26-05, 05:37 PM
  #59  
Powered by** Rotary

Thread Starter
 
BoOsTin FD's Avatar
 
Join Date: Feb 2002
Location: St. Louis
Posts: 2,369
Received 0 Likes on 0 Posts
It was 50 degrees outside i doubt the smic wasn't cooling it enough. I know when i pulled over, the intake side of the IC was mild not hot or anything.