Originally Posted by armans
There are 3 input resistors in each fan (in the drawing - the 4 tabs on the circle that has letter M inside, one is ground and the other three are inputs).

If you track backwards from those tabs to relays, it becomes kinda obvious what's going on.

A) If only relay No.1 is activated, both fans get 1 input (hence LOW speed).
B) Otherwise if only relays No.2 and No.4 are activated, both fans again get 1 input (hence LOW speed).
C) If relay No.3 joins to either A) or B) above, it is MEDIUM speed.
D) If relay No.3 joins to BOTH A) and B) then its HIGH speed.

Obviously if your ECU supports PWM fan output, that'd be the way to go.
Where are the resistors in the diagram? Can you circle them for me

I don't know how the fans are wired, but I don't think the orange line is a power "input" since it is connected to ground via Relay 3.
Old 05-25-24, 02:27 PM
  #152  
Built Not Bought
Tenured Member 15 Years
iTrader: (14)
 
TwinCharged RX7's Avatar
 
Join Date: May 2008
Location: Stamford, CT
Posts: 4,325
Likes: 0
Received 903 Likes on 562 Posts
Originally Posted by armans
There are 3 input resistors in each fan (in the drawing - the 4 tabs on the circle that has letter M inside, one is ground and the other three are inputs).
How you describe the system logic makes sense and how I thought it worked. But where are you seeing 3 inputs and 1 ground. This looks like the 3rd relay (all the way to the right) activates to ground (orange line). That would mean each motor has 2 inputs for voltage and 2 grounds.

am I reading it wrong? See 2 grounds circled in red.


Old 05-25-24, 03:18 PM
  #153  
~17 MPG
Tenured Member 20 Years
iTrader: (2)
 
scotty305's Avatar
 
Join Date: Jan 2004
Location: Bend, OR
Posts: 3,346
Received 252 Likes on 167 Posts
TwinChargedRX7 is correct and Armans is wrong, there are two power inputs and two grounds per fan. If you understand how circuits work you can manually trigger the relays, and measure the voltage at the fan connectors.

I tested the operation a few years ago; although I don't understand the exact details of how the fan motor internals work, their behavior is clearly three speeds each. In hindsight, I don't think it's dumb to have duplicated relays (2 and 4 both serving the same purpose). Spreading the load to two relays might help with longevity, assuming those two relays are active more often than the others. If I'm being picky, it would have been better to locate the fan relays near the battery to reduce the length of heavy wire between the battery and the fans.
https://www.rx7club.com/3rd-generati...0/#post4770880

Last edited by scotty305; 05-25-24 at 03:25 PM.
Old 05-25-24, 04:45 PM
  #154  
Senior Member
Tenured Member 05 Years
iTrader: (2)
 
armans's Avatar
 
Join Date: Oct 2014
Location: America's finest city
Posts: 466
Received 26 Likes on 25 Posts
Ok I stand corrected - I overlooked that part that it was a switched ground connection to relay N3. That means there should be some "clever" circuitry in the fan that bumps the speed if we ground that wire (relay N3)..?
I reinstalled my fans back couple weeks ago, If I still had them out I'd open them and check the inside out of curiosity.
Old 05-25-24, 06:33 PM
  #155  
Senior Member
Tenured Member 15 Years
 
Billj747's Avatar
 
Join Date: Oct 2006
Location: SoCal
Posts: 274
Received 163 Likes on 80 Posts
An idea popped into my head. If the fan has two power inputs and only one ground, that could be the medium speed, then there must be circuitry within the fan where when it gets the second ground, it goes to the high speed. This could be tested by running battery voltage directly to both power inputs, and then play with grounding one or both of the ground wires to see if that changes the speed.

Originally Posted by TwinCharged RX7
How you describe the system logic makes sense and how I thought it worked. But where are you seeing 3 inputs and 1 ground. This looks like the 3rd relay (all the way to the right) activates to ground (orange line). That would mean each motor has 2 inputs for voltage and 2 grounds. am I reading it wrong? See 2 grounds circled in red.
I think those numbers just designate which fans the line grounds. The left #2 circle designates that it grounds the #2 fan, and the #1&2 on the right designate that line grounds fans 1&2 (which they do). Typically resistors have a zigzag symbol in a diagram, and I don't see a key in the manual or diagram that explains what what those circled numbers mean, or expand if they are a resistor or something else. So my guess is on just a fan grounding designation.

Last edited by Billj747; 05-26-24 at 08:41 AM.
Old 05-25-24, 07:41 PM
  #156  
Senior Member
Tenured Member 05 Years
iTrader: (2)
 
armans's Avatar
 
Join Date: Oct 2014
Location: America's finest city
Posts: 466
Received 26 Likes on 25 Posts
Well, I've just tested it. It was easier for me to do the test as I've a single solid state relay with PWM setup so I just needed to ground that wire.
In this pic I shorted blue/orange wire from B2-03 connector (for N3 relay) to the frame and it gave more oomph to the fans. I did it in test mode, car not running.
Surprising revelation for me) - turns out so far I haven't even used that HIGH speed mode lol. Although no problems with the temps (street driven) - stable ~185F.

Old 05-25-24, 08:01 PM
  #157  
Senior Member
Tenured Member 15 Years
 
Billj747's Avatar
 
Join Date: Oct 2006
Location: SoCal
Posts: 274
Received 163 Likes on 80 Posts
Awesome job. Were you able to also energize relays 1 then 1,2,4 to see low and medium before grounding that B2-03 for high?
Old 05-26-24, 05:16 PM
  #158  
Senior Member
Tenured Member 05 Years
iTrader: (2)
 
armans's Avatar
 
Join Date: Oct 2014
Location: America's finest city
Posts: 466
Received 26 Likes on 25 Posts
Actually no. My SS relay is in the place of stock N1 relay. Other three relay connectors are left unused. I merely jumped the Blue/Orange wire to the ground.
Old 05-26-24, 11:44 PM
  #159  
~17 MPG
Tenured Member 20 Years
iTrader: (2)
 
scotty305's Avatar
 
Join Date: Jan 2004
Location: Bend, OR
Posts: 3,346
Received 252 Likes on 167 Posts
I don't plan to repeat this test soon, but if my notes from 2005 are accurate you will get medium fan speed if any two of the relay triggers are active. It didn't seem to matter whether relays 1&2 were triggered, or 1&3, or 2&3, the fan speed sounded 'medium' to me in each situation.




It would be interesting to repeat the test and measure current, now that DC clamping current meters are more commonly available.
The following users liked this post:
ColdFeet (05-27-24)
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
arghx
3rd Generation Specific (1993-2002)
41
03-29-18 03:24 AM
jackhild59
2nd Generation Specific (1986-1992)
7
06-12-12 07:59 AM
Directfreak
1st Generation Specific (1979-1985)
24
04-30-07 12:36 AM
Rx7_Nut13B
3rd Generation Specific (1993-2002)
4
03-10-07 09:01 AM
Alpine
3rd Generation Specific (1993-2002)
3
12-22-04 02:47 AM



Quick Reply: DaleClark's all about fan control and the fan system



All times are GMT -5. The time now is 06:30 PM.