water temp don't work
#1
Clogged cat
Thread Starter
iTrader: (3)
Join Date: Sep 2002
Location: Orange County, CA
Posts: 2,000
Likes: 0
Received 0 Likes
on
0 Posts
water temp don't work
Hey today I tried to install my Autometer water temp gauge but it doesn't work.
I put the sender in the plastic part instead of the water pump cause I was scared to break it.
Is that why it doesn't work or is it because of bad wiring? The needle stays at 100 and doesn't move.
Thanks a lot!!
I put the sender in the plastic part instead of the water pump cause I was scared to break it.
Is that why it doesn't work or is it because of bad wiring? The needle stays at 100 and doesn't move.
Thanks a lot!!
#2
Has been.. hangin' around
Join Date: Mar 2001
Location: Milpitas, CA
Posts: 2,618
Likes: 0
Received 0 Likes
on
0 Posts
oh, because the sender has to be grounded. Since you put it in a plastic piece, it's not grounded.
You can solder on a ground wire to the body of the sender and ground it to the chassis.. That's why I didn't tell you to use the plastic piece
Oh well
You can solder on a ground wire to the body of the sender and ground it to the chassis.. That's why I didn't tell you to use the plastic piece
Oh well