2nd Generation Specific (1986-1992) 1986-1992 Discussion including performance modifications and technical support sections.
Sponsored by:

Fuel issues with AP engineering Apex'i.

Thread Tools
 
Search this Thread
 
Old 01-25-10, 02:37 PM
  #1  
Senior Member

Thread Starter
 
McCarthy's Avatar
 
Join Date: Feb 2007
Location: Surrey, England
Posts: 368
Likes: 0
Received 0 Likes on 0 Posts
Fuel issues with AP engineering Apex'i.

Hey people,

I was hoping if anyone could shed some light on a fueking issue i have. I have a A'pexi PFC from AP Engineeing on S5 FC3S. All is fine aside from the fuel pump. I have no signal going to it = 0 fuel pressure.

Running walbro pump which works on the bench out of the car
Aftermarket fuel pressure regulator
1680 bosch injecotrs

No i should point out that even with the stock ECU the pump isn't firing correctly although its making noise. readings of around 5v but no

Can you bypass the fuel resister relay simply using a 4 pin relay like you do with a mircotech unit?

Anyideas would be great
Old 01-25-10, 04:11 PM
  #2  
rotorhead

iTrader: (3)
 
arghx's Avatar
 
Join Date: Aug 2004
Location: cold
Posts: 16,185
Received 432 Likes on 265 Posts
Is the circuit opening relay under the dash getting triggered properly?

Also, this is a series 5 JDM car I'm guessing since you are in the UK?
Old 01-25-10, 04:34 PM
  #3  
Senior Member

Thread Starter
 
McCarthy's Avatar
 
Join Date: Feb 2007
Location: Surrey, England
Posts: 368
Likes: 0
Received 0 Likes on 0 Posts
Yes its JDM car.

What i was hoping to do is eliminate the stock relays from the equastion. I usually run the mircotech set up where by the pump(s) are run off a seperate 4 pin relay using a mircotech specific loom.

I was wondering if anyone has needed tp do this on the Apex'i when using on the FC3 or id any problems have been experienced when using the AP Engineeing version.
Old 01-25-10, 05:03 PM
  #4  
rotorhead

iTrader: (3)
 
arghx's Avatar
 
Join Date: Aug 2004
Location: cold
Posts: 16,185
Received 432 Likes on 265 Posts


FD/Power FC pin 1T is the fuel pump relay trigger. You can use that to trigger your own fuel pump relay, bypassing all the factory stuff completely.
Attached Thumbnails Fuel issues with AP engineering Apex'i.-pfc_pinout.jpg  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
alphawolff
1st Generation Specific (1979-1985)
17
11-17-15 05:57 PM



Quick Reply: Fuel issues with AP engineering Apex'i.