oh alright, i wasnt really thinking, but how come there arent ones on stock electrical systems?

Last edited by liquidferrum; 10-06-03 at 05:48 PM.
Old 10-06-03, 07:09 PM
  #27  
In Full Autist Cosplay

iTrader: (1)
 
Black13B's Avatar
 
Join Date: Nov 2002
Location: Alberta
Posts: 2,330
Likes: 0
Received 0 Likes on 0 Posts
There is. They are called fuses.

Fuses blow and need to be replaced, breaker switches will kick off and can just be flipped back on rather than replaced.

We need them because there aren't 2 or 4 gauge wires bone stock that are of such excessive length. When you are relocating you will have some big wires running along the chassis. Namely the power wire is big and the chassis is a big ground. Just like RETed said. You DO NOT want a short, because it will cause alot of damage.
Old 10-07-03, 10:47 AM
  #28  
Senior Member

 
liquidferrum's Avatar
 
Join Date: Jul 2002
Location: Wisconsin =(
Posts: 251
Likes: 0
Received 0 Likes on 0 Posts
oh alright, the fuses are what i was getting at, i should have just asked why the stock fuses wouldnt do the trick, thanks for taking the time to clear that up for me =)
Old 11-07-03, 09:03 PM
  #29  
Rotary Enthusiast
Veteran: ArmyTenured Member 20 Years
iTrader: (5)
 
Net Seven's Avatar
 
Join Date: Apr 2002
Location: Mesa, AZ
Posts: 1,470
Received 15 Likes on 11 Posts
where did you guys run the wire from the stock connectors and alterator to the bin?
Old 11-07-03, 10:15 PM
  #30  
Rotary Enthusiast
Veteran: ArmyTenured Member 20 Years
iTrader: (5)
 
Net Seven's Avatar
 
Join Date: Apr 2002
Location: Mesa, AZ
Posts: 1,470
Received 15 Likes on 11 Posts
Do you need 2 circuit breakers or just one circuit breaker and a fuse? On the diagram you have 2 circuit breakers...
Old 11-10-03, 11:25 PM
  #31  
Senior Member

 
eyeoutthere's Avatar
 
Join Date: Nov 2002
Location: Owego NY
Posts: 379
Likes: 0
Received 1 Like on 1 Post
You really don’t need any circuit breakers. Two fuses will do just fine and will be much cheaper. If you are blowing fuses or tripping breakers there is something wrong.

Just remember that circuit breakers are nothing more than reset-able fuses. They are interchangeable. What you use in your setup is up to you.

It is kind of convenient to be able to flip a switch when working on the electrical system, as apposed to disconnecting the battery.

…and yes, whatever you use, you should have two of them.

I have a question though.
Does it matter what type of power wire we use?

A friend of mine said that the High-Strand-Count car audio power wire should not be used for battery relocation, and something with a lower stand count should be used instead. Is this true? Why?
Old 11-10-03, 11:40 PM
  #32  
Senior Member

 
jinx22630's Avatar
 
Join Date: Mar 2003
Location: Front Royal, Virginia
Posts: 328
Likes: 0
Received 0 Likes on 0 Posts
How are you anchoring your battery to the floor of the storage bin? Did I miss that?
Old 11-11-03, 06:49 PM
  #33  
Full Member

Thread Starter
 
smith88's Avatar
 
Join Date: Jun 2001
Location: IL
Posts: 161
Likes: 0
Received 0 Likes on 0 Posts
I'm anchoring my battery to the bin floor with J-hooks. I had to drill 2 holes and cut off the lengthy J-hooks, but it worked.
I only have 1 breaker back by my battery. I had to run a Power and Ground up to my remote terminals in the engine bay. Power on the passenger side, ground on the drivers side. And then I hooked up the stock battery wires to the newly ran wires onto the terminals.
Everything is working great. I even took it to a dragstrip, and they didn't even check the inside of my car or under the hood. Ran a slow time though, think I lost a vaccuum hose.
Old 11-11-03, 07:38 PM
  #34  
Senior Member

 
jinx22630's Avatar
 
Join Date: Mar 2003
Location: Front Royal, Virginia
Posts: 328
Likes: 0
Received 0 Likes on 0 Posts
Originally posted by jinx22630
How are you anchoring your battery to the floor of the storage bin? Did I miss that?
Ok, cool, just wanted to make sure you didn't get decapitated if you were ever in a roll-over. Just make sure that bitch isn't going anywhere!!!!!!
Old 12-01-03, 01:30 AM
  #35  
Rotary Enthusiast
Veteran: ArmyTenured Member 20 Years
iTrader: (5)
 
Net Seven's Avatar
 
Join Date: Apr 2002
Location: Mesa, AZ
Posts: 1,470
Received 15 Likes on 11 Posts
Did you guys run the wire inside the car or outside the car? What way is better to do?
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Turblown
Vendor Classifieds
12
10-17-20 03:25 PM
FC3S Timmy
2nd Generation Specific (1986-1992)
16
10-03-15 01:08 AM
FC3S Timmy
2nd Generation Specific (1986-1992)
8
10-02-15 08:08 AM
RuffRx7
3rd Generation Specific (1993-2002)
4
10-01-15 03:08 AM
choddaboy
Introduce yourself
0
09-26-15 06:35 PM



Quick Reply: Battery Relocation



All times are GMT -5. The time now is 04:11 AM.