yeah, a piece of beach sandals but chinese rubber slippers are easier to find
Old 04-11-05 | 08:44 PM
  #27  
rwatson5651's Avatar
79 w 13B4port
iTrader: (5)
 
Joined: Jan 2005
Posts: 1,908
Likes: 53
From: Alabama
I'm running the mallory comp 70 with a holley 1-4 psi regulator.

Its a little expensive but it is very quiet and seems to keep up with my 13b street port.

If money was an issue i'd use the carter, they seem to be very popular.
Old 04-11-05 | 08:45 PM
  #28  
Siraniko's Avatar
RX for fun
iTrader: (13)
 
Joined: Aug 2001
Posts: 15,926
Likes: 22
From: Socal
huh!!! Holley reds are much more expensive than the carter pump.
Old 04-11-05 | 10:37 PM
  #29  
kuhlrx7's Avatar
Unconfirmed
 
Joined: Oct 2002
Posts: 632
Likes: 0
From: florida
I had the same problem on a large street port 12a . I solved the problem with a larger needle valve. you need no smaller than a 2.0 I also ran a larger fuel line to the pump and ran the pressure higher than sugested. you will need to play with the fuel pressure to find the right spot. It will be higher than 4.25 and lower than 6lbs. mine was a repetable drop just after the shift to 3rd till I got it right. its been a while since I had that set up but I think my pressure setting was around 5 1/2lbs.
Old 04-11-05 | 11:31 PM
  #30  
DAVID GRIMES's Avatar
How About A Cup Of STFU
 
Joined: Sep 2004
Posts: 1,552
Likes: 0
From: ALBANY, GA
Thanks to all for the info.

So, kuhlrx7, was it enough carb for your large street port 12A ? I never got anybody to say if it is sufficient, marginal or insufficient for my application ( ported 13B 4port ).
Old 04-11-05 | 11:45 PM
  #31  
kuhlrx7's Avatar
Unconfirmed
 
Joined: Oct 2002
Posts: 632
Likes: 0
From: florida
I would say sufficient. based on my experance. if you went to a larger port you would want to go up in size though.
Old 04-12-05 | 03:33 AM
  #32  
karism's Avatar
Adolf Hitler Verfechter
 
Joined: Sep 2002
Posts: 969
Likes: 0
From: Northern South Africa
David :Can you perhaps tell us what size venturies your using?I agree with Mr.Kuhl,It should be sufficient,depending on your venturi size.

karis
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Th0m4s
Build Threads
25
02-26-19 03:04 AM
astrum
2nd Generation Specific (1986-1992)
24
11-15-17 09:44 AM
sYnth.
Build Threads
0
08-19-15 07:27 PM



Quick Reply: Anybody who has ever owned or worked on a Mikuni 44PHH...



All times are GMT -5. The time now is 12:50 PM.